Ensuring the Accuracy and Reliability of NDT Instruments, Probes and Standards
Welcome to our Calibration Services Landing Page for mobile devices
Our Calibration Services
Calibration: Ensuring the Quality of Your Test and Measuring Results
At FOERSTER, we understand the critical importance of accurate and reliable test and measuring results in non-destructive testing (NDT). Calibration lies at the heart of maintaining the integrity of your instruments, probes and standards. It involves comparing your measured values with traceable standards to guarantee precision and consistency.
Why Calibration Matters
Calibration is essential for demonstrating the high quality of your test and measurement results. It enables you to accurately quantify parameters such as coercive force, magnetic flux density, and permeability, providing confidence in the reliability of your NDT processes. Regularly recalibrating your systems and equipment ensures that your results meet industry standards and comply with regulations.
Sample Certificates and Additional Specifications
To assist you in finding the precise calibration service you need, we provide sample certificates showcasing the norms covered in our calibration processes. These certificates offer valuable insights into the parameters we calibrate and the meticulous standards we adhere to. Furthermore, if your specific requirements extend beyond our standard calibration offerings, we offer the flexibility to accommodate additional specifications upon request.
Our Comprehensive Factory Calibration Service
At FOERSTER, we offer a comprehensive factory calibration service designed to meet your specific needs. Our skilled technicians meticulously check your FOERSTER systems or devices for perfect function and compliance with performance parameters. This thorough calibration process ensures that the high quality of your products is maintained throughout their lifecycle.
Transparent Repair Process
In the rare event that a repair is required during the calibration process, we prioritize transparency and customer satisfaction. You will receive a detailed estimate before any work is carried out, ensuring that you are fully informed about the scope and cost of the repair. Our goal is to minimize downtime and swiftly restore your equipment to optimal working condition.
Explore our range of calibration services today and discover the quality assurance that sets us apart.
Article description |
Order - Nr. |
Sample |
DEFECTOMETER 2.837 |
1459147 |
|
DEFECTOMETER M 1.837 |
1880756 |
|
Electrical check of calibration block (3x notch) (2.142/ 2.154/ 2.164/ 2.835/ 2.836/ 2.837/ 1.837) | 2325233 |
|
Dakks akkredited depth measurement of calibration block (3x notch) (1.837.01-11xx) | 2345501 |
|
Depth measurement of calibration block (3x notch) (2.142/ 2.154/ 2.164/ 2.835/ 2.836/ 2.837/ 1.837) | 2325241 | |
Electrical check of customer specific calibration block (1x notch) | 2331390 | |
Conductivity measurement of calibration block at 60kHz (only Nfe, Ti, Aust) | 2345587 | |
Depth measurement of customer specific calibration block (1x notch) | 2331403 | |
Depth measurement of 1 test defect in customer specific part | 2343673 | |
Calibration of 1 DEFECTOMETER probe |
2826313 |
|
Calibration of 1 DEFECTOSCOPE probe |
2244691 |
|
Calibration of 1 MAGNATEST probe |
2244667 |
Article description |
Order - Nr. |
Sample |
MAGNETOSCOP 1.070 incl. probe |
2084970 | |
MAGNETOSCOP 1.070 | 2084988 | SAMPLE |
MAGNETOSCOP 1.070 probe | 2084996 | |
MAGNETOSCOP 1.069 incl. probe | 1805053 | |
MAGNETOSCOP 1.069 probe | 2075024 | |
MAGNETOMAT 1.790 | 2161850 | |
MAGNETOMAT 1.790 probe | 2084996 | |
MAGNETOMAT 1.782 incl. probe | 1832328 | |
MAGNETOMAT 1.782 probe | 2075032 | |
Reference standard permeability 1.070 (30kA/m) | 2085003 | SAMPLE |
Reference standard permeability 1.068 / 1.069 (10kA/m) | 1269291 | |
1-20 permeability measurements with certificate (µr 1.0-2.0) | 2085038 | |
Permeability measurements from measurement 21 | 2085046 | |
1-20 field measurements with certificate | 2085054 | |
Field measurements from measurement 21 | 2085062 |
Article description |
Order - Nr. |
Sample |
SIGMATEST 2.070 calibration instrument with probe and double standard |
2257688 |
|
SIGMATEST 2.070 calibration of 1 probe |
2257700 |
SAMPLE |
SIGMATEST 2.069 calibration instrument with probe and double standard |
1881647 |
|
SIGMATEST 2.069 calibration of 1 probe |
2219824 |
|
SIGMATST 2.069/2.070 calibration of 1 8mm flex probe | 2219832 |
|
Readjustment of 1 probe (if the calibration of a probe failed 2.069/2.070) |
2306735 |
|
Readjustment of 1 flex-probe (if the calibration of a probe failed 2.069/2.070) | 2321629 |
|
Addon calibration (2.070/2.069 instrument): Measurement of the excitation frequencies |
2306743 |
SAMPLE |
Addon calibration (2.070/2.069 probe or standard): Measurement with different limits (example: 1%IACS deviation) |
2306751 | SAMPLE |
Addon calibration (2.070/2.069 probe or standard): List of the 10 individual measurement values for each frequency |
2306760 |
SAMPLE |
Addon calibration (probe): 10 manual measurements on 7 calibration blocks in the range between 14-64 %IACS |
2339803 | |
Addon calibration (probe): Repeat the 10 manual measurements on 7 calibration blocks in the range between 14-64 %IACS after minimum 15 minutes |
2339811 | |
Conductivity measurement with certificate of a customer part (NPL) |
2278120 |
SAMPLE |
Addon calibration (probe): 5 measurements on a calibration block with 48%IACS with a given lift-off height e.g. 75µm, 250µm or 500µm and having a difference smaller +-0.5%IACS |
2339838 | |
Addon calibration (external temperature sensor 2.069) calibration at T1=20°C and T2=30°C with certificate |
2340836 | |
Addon calibration (2.070/2.069 probe or standard): Appendix for verified standards DGQT 4.2.0368 or AITM6-6008 |
2306778 |
|
Addon calibration (2.070/2.069 probe or standard): Appendix for verified standard AITM6-6008 |
|
|
Addon calibration (2.070/2.069 probe or standard): Appendix for verified standard IGC 04.25.120 |
|
|
Addon calibration (2.070/2.069) One frequency (60kHz, 120kHz, 240kHz, 480kHz or 960kHz) |
2321637 | |
Addon calibration (2.070/2.069 probe or standard) Integration of customer specific data afterwards or providing lost certificates again |
2322315 | |
Further standards must be verified on an individual basis. | ||
Calibration standard based on NPL (SIGMATEST 2.070) (5 frequencies) |
2278111 |
SAMPLE |
Calibration standard based on PTB (SIGMATEST 2.069) (5 frequencies) |
2826348 |
SAMPLE |
Addon calibration (probe): Check if a slight manual pressure (5 measurements) does not cause a variation greater than +-0.5 %IACS on a calibration block with 48%IACS |
2339820 | |
Conductivity measurement with certificate of a customer part (PTB) |
2306727 |
SAMPLE |
What is the difference between PTB and NLP?
Find out more here.
Article description |
Order - Nr. |
Sample |
Factory calibration of hand test probe with certificate Note: includes the incoming inspection of the probe (does not include the incoming inspection & function test of the instrument) |
2229641 |
SAMPLE |
Incoming inspection & function test of instrument (e.g. SONODUR 3, MIC 10) Note: Required if certification of the probe must state the specific instrument (otherwise a factory instrument will be used for the certification of the probe) |
4990200 |
|
Calibration according to DIN 50159-2; DAKKS certificate for SONODUR instrument and 1 probe Note: Requires factory calibration of the probe (2229641) and incoming inspection & function test of instrument (4990200) beforehand |
2231115 |
SAMPLE |
Article description |
Order - Nr. |
Sample |
TCM 2.142 calibration of instrument | 2319993 | SAMPLE |